Gas Transmitters, Universal Displays, Controllers
The FlexVu® Model UD10 Universal Display is a display and communicator for a wide range of toxic and combustible gas sensors.
The FlexVu® performs as a gas transmitter and controller.
It provides one-person non-intrusive calibration and device configuration (without zone declassification) using hand-held magnetic tool (4 magnetic switches on display panel) or Fieldbus communicator, local navigation and adjustment of parameters like alarm thresholds, measurement range, calibration gas concentration, local event logging.
It's equipped with backlit and heated LCD display which continuously displays the gas level, gas type, unit measured and informs about supply status, alarm levels and faults. The display has real time clock and alarm and fault memory.
The UD10 informs about the sensor degree of wear and tear.
UD10 with toxic gas detector GT3000
The display outputs: 4-20 mA with HART (linear isolated corresponds with gas concentration, information about device status), Modbus RS485, relays: 3 independently programmed alarm relays, one fault relay.
It works with detectors:
- IR Point HC Gas Detectors: PIR9600 or PIRECL Eclipse®, as well as PointWatch PIR9400 (obsolete)
- IR Open Path Gas Detectors: FlexSight™ LS2000 or Eclipse OPECL (obsolete)
- Catalytic Combustible Gas Detectors CGS directly or via transmitter Model 505
- Toxic Gas Detectors GT3000, C706X and NTMOS (obsolete)
- Acoustic Gas Leak Detector FlexSonic®
It can also co-operate with addressable loop hazard monitoring system Eagle Quantum Premier®.
Approvals:
- It is rated ATEX / IECEX: Ex d IIC T5 Gb for hazardous areas.
- Available SIL2 models certified to IEC61508 by Exida®
Warranty: 18 months from the date of production
Single-channel gas controllers R8471 are designed to be mounted in 19" rack. They were is designed for continuous monitoring of a 4 to 20 mA signal that is generated by an electrochemical sensor or a catalytic sensor/transmitter combination.
Controller models are available to accommodate a variety of combustible gas, oxygen and toxic gas sensors.
Microprocessor-based controller continuously monitors the analog 4-20mA output from any Det-tronics gas detector: transmitter Infiniti (all gas detectors), transmitter 505 for CGS gas detector, junction box in case of C706X or PIR9400 detectors and from Eclipse gas detector directly.
The R8471 continuously compares the analog signal with programmed alarm thresholds.
The controller provides visual indication from: high-visibility bar-graph of gas concentration level currently measured by the detector, high intensity alarm and status LED's, three-digit display for gas concentration or fault code readings. It is easily field programmable by use of two pushbuttons on the front panel.
The device allows the calibration without the hazardous area de-classification. It also indicates the end of sensor's life.
Standard 4-20mA output. Optional outputs: three alarm and one fault relay.
Approvals: FM, CSA, CE and performance tests acc. to EN 60079-29-1.
NOTE:
The product is obsolete (withdrawn from production). It will be no longer repaired. Please contact IP&S for the selection of a replacement controller.
The Infiniti® U9500 transmitter allows local readings, provides local set-up and calibration capabilities for all kinds of Det-tronics combustible and toxic gas detectors: combustible CGS, toxic and oxygen, PointWatch™ PIR9400, PointWatch Eclipse® PIRECL. Transmitter allows local programming of alarm thresholds, measuring range and calibration gas concentration.
The Infiniti® is equipped with alphanumeric display showing gas concentration and informing about alarm conditions and faults. The U9500 displays sensor sensitivity and informs about sensor's end of life.
U9500 Infiniti® with combustible gas detector CGS
Infiniti® standard output is linear isolated 4-20mA analog output proportional to gas concentration in % of LEL. It also presents the status and calibration information. Optional outputs include: three independently programmable alarm relays (high, low and auxiliary) one fault relay.
Transmitter allows non-intrusive single person calibration using internal magnetic switch. He is compatible with Eagle Quantum Systems.
Approvals:
- Expolsion proof ATEX / IECEX certified: Ex d IIC T5-T6 Gb
NOTE:
The product will be withdrawn from production soon. It is offered as replacement or spare part only. It can be repaired. Please contact IP&S for the selection of a replacement controller/transmitter.